Deltronix Medical Devices
Ribeirão Preto, Brazil
Ribeirão Preto manufacturer of electrosurgical units and accessories for hospitals, producing since 1970.
We use essential cookies to run this site. With your permission we also remember your language, count visits to improve the directory, and load third-party content such as Google Translate and videos. You can change your choice at any time. Cookie Policy
Discover surgical instruments, manufacturers & suppliers, medical exhibitions and industry insights
5 electrosurgical instruments manufacturers in Brazil are listed in this directory. All of them are based in Brazil. Main locations: Ribeirão Preto, Rio de Janeiro, São Paulo, Rio Claro. Each profile shows the business type, product categories and official contact details published by the company; use the filters to narrow the list.

Ribeirão Preto, Brazil
Ribeirão Preto manufacturer of electrosurgical units and accessories for hospitals, producing since 1970.

Rio de Janeiro, Brazil
Rio de Janeiro surgical materials producer founded in 1928, making custom parts and surgical instruments for all specialties.

São Paulo, Brazil
São Paulo manufacturer of electrosurgical and surgical equipment for multiple specialties, active since 1988.
Brazil
Brazilian developer, manufacturer and distributor of medical-hospital equipment and electrosurgical devices, registering products since 2011.

Rio Claro, Brazil
Brazilian manufacturer, founded in 1995 in Rio Claro, São Paulo, of spine, trauma and cranio-maxillofacial implants, TMJ prostheses and related instruments.
5 companies match this category and country as a manufacturer. The list updates automatically when profiles are added or changed.
Profiles are compiled from each company’s own website and public sources; verified details are marked on the profile. Featured or Sponsored labels are paid placements, not endorsements. See how listings are checked.
Open the company profile for its official website, e-mail and phone details, and contact the company directly. SurgiFacts.com does not sell instruments.


Regulator: Agência Nacional de Vigilância Sanitária (ANVISA)
Brazil classes devices I–IV under RDC 751/2022: Classes I–II are notified (notificação), Classes III–IV registered (registro), via a Brazilian holder.
From the sourced RDC 751/2022 entry, checked 29 October 2026. General information, not legal advice. Requirements for Brazil · All medical certifications
Brazil regulates medical devices under ANVISA's RDC 751/2022, with four risk classes:
Only a Brazilian legal entity (a manufacturer or importer) can hold the notification or registration, so foreign manufacturers authorize a local holder. Labels and instructions must be in Portuguese, and some devices also need INMETRO conformity certification. See the medical certifications page.
Only a Brazilian legal entity (a manufacturer or importer) can hold an ANVISA notification or registration (the "detentor"). The holder needs an ANVISA company operating authorization (AFE), files in its own name, communicates changes and keeps the technical dossier. The foreign manufacturer authorizes it through a consularized or apostilled declaration.
If your distributor is the holder, changing distributor can mean moving registrations. Many foreign manufacturers therefore use an independent holder so they can change distributors more freely. That is a commercial practice, not a legal requirement. Brazilian companies, currently more than 60, are listed on the Brazil country page.
RDC 751/2022 requires labels and instructions for use in Portuguese. They must include the Brazilian holder's name and address and, where applicable, manufacturing and expiry dates. For reusable devices, the information must cover reprocessing: cleaning, disinfection, packaging, the re-sterilization method and any limit on the number of reuses.
Label artwork and IFU are submitted with the notification or registration petition. A manufacturer exporting to Brazil therefore needs validated reprocessing instructions translated into Portuguese before filing. Some devices also need INMETRO conformity certification, so check whether that applies. See the medical certifications page.
For imported Class I and II notifications, RDC 751/2022 asks for a declaration from the legal manufacturer. It must authorize the Brazilian applicant and confirm knowledge of and compliance with B-GMP. It must be consularized or apostilled, in Portuguese, English or Spanish (or with a sworn translation), and no more than two years old if it states no validity. Class III and IV registrations also need proof of registration or free sale in the country of manufacture or sale.
Petitions missing mandatory documents can be refused without a technical query. Listed Brazilian companies are in cities such as São Paulo, Rio Claro and Ribeirão Preto; see the Brazil country page.
Class I, under Rule 6 of Annex I to RDC 751/2022. Transient surgically invasive devices are Class II unless they are reusable surgical instruments (Class I) or meet higher-risk conditions, such as contact with the heart, central circulatory system or central nervous system, which can make them Class IV. Class I and II devices are notified rather than registered.
Note that RDC 751 defines reusable surgical instruments more widely than some other jurisdictions: the definition covers instruments that may or may not be connected to an active device. Where several rules apply, the strictest applies, and ANVISA may challenge the declared class. See the medical certifications page.