
ABC Instrumentos
Brazil
Brazilian manufacturer of surgical and dental hand instruments, certified to ISO 9001 and ISO 13485.

American Burrs
Palhoça, Brazil
Santa Catarina manufacturer of dental burs and rotary instruments, ISO 13485 certified, exporting internationally.
Angelus Indústria de Produtos Odontológicos
Londrina, Brazil
Londrina dental products manufacturer exporting to more than 80 countries, with CE MDR certification.

Bhio Supply
Esteio, Brazil
Esteio-based developer and producer of videolaparoscopic instruments for minimally invasive surgery, founded in 1993.

Bio-Art Equipamentos Odontológicos
São Carlos, Brazil
São Carlos manufacturer of dental equipment such as articulators, autoclaves and laboratory devices, founded in 1977.
Jaú, São Paulo orthopedic implant manufacturer active since 1988, ISO 13485 certified and holding Anvisa GMP certification.

Bionnovation Biomedical
Bauru, Brazil
Bauru company producing bone graft biomaterials, membranes, dental implants and surgical instruments since 1993.

Conexão Sistemas de Prótese
Arujá, Brazil
Brazilian dental implant and prosthetic components company in Arujá, São Paulo, founded in the early 1990s.

Confiance Medical
Rio de Janeiro, Brazil
Rio de Janeiro manufacturer of video-surgery equipment such as xenon light sources and CO2 insufflators.
Brazilian manufacturer of tabletop autoclaves and biosafety equipment for dental, medical and veterinary use, exporting to 12 countries.

Dabi Atlante
Ribeirão Preto, Brazil
Ribeirão Preto dental equipment manufacturer founded in 1946, producing chairs, autoclaves and handpieces.

Deltronix Medical Devices
Ribeirão Preto, Brazil
Ribeirão Preto manufacturer of electrosurgical units and accessories for hospitals, producing since 1970.

Dental Speed
São José, Brazil
Santa Catarina dental products distributor, part of Henry Schein, operating since 1996.

Dentfix
Santa Rita do Passa Quatro, Brazil
São Paulo state manufacturer of titanium dental implants and prosthetic components, founded in 1997.
Dentflex
Ribeirão Preto, Brazil
Ribeirão Preto manufacturer of dental equipment made in Brazil, active since 1991.

Dentscler
Ribeirão Preto, Brazil
Ribeirão Preto manufacturer of dental handpieces and equipment for dentistry, aesthetics and medicine, founded in 1996.
DFV
Valença, Brazil
Valença, Rio de Janeiro optical equipment maker producing colposcopes, surgical microscopes and lighting, with 80 years of experience.

Driller
Carapicuíba, Brazil
Carapicuíba, São Paulo manufacturer of health products such as surgical motors and dental equipment.

DSP Biomedical
Campo Largo, Brazil
Paraná producer of dental implants and products for dentistry, oral-maxillofacial surgery and implantology.

EDLO
Canoas, Brazil
Brazilian surgical instrument brand from Canoas covering conventional, titanium and video-surgery instruments.

EFF Dental
São Paulo, Brazil
São Paulo manufacturer of prosthetic dental components compatible with more than 120 implant systems.

Erwin Guth
Brazil
Brazilian manufacturer of precision surgical and dental instruments since 1957, with over 9,800 instrument types.
FAGA Medical
Bauru, Brazil
Bauru developer and manufacturer of surgical and hospital equipment and devices, with export partnerships.

FAMI Tecnologia Médica
São Caetano do Sul, Brazil
São Caetano do Sul manufacturer of sterilization containers and health products, with origins in 1915.
Business types in Brazil
Cities in Brazil
Medical exhibitions in Brazil


Regulation in Brazil
Regulator: Agência Nacional de Vigilância Sanitária (ANVISA)
Brazil classes devices I–IV under RDC 751/2022: Classes I–II are notified (notificação), Classes III–IV registered (registro), via a Brazilian holder.
From the sourced RDC 751/2022 entry, checked 29 October 2026. General information, not legal advice. Requirements for Brazil · All medical certifications
Frequently asked questions
How does ANVISA regulate medical devices in Brazil?
Brazil regulates medical devices under ANVISA's RDC 751/2022, with four risk classes:
- Class I and II: notification (notificação), with no technical review before the product is regularized; ANVISA can check documents or inspect later.
- Class III and IV: registration (registro), with a technical dossier and an ANVISA Brazilian GMP (B-GMP) certificate. Registration is valid for 10 years and renewable.
Only a Brazilian legal entity (a manufacturer or importer) can hold the notification or registration, so foreign manufacturers authorize a local holder. Labels and instructions must be in Portuguese, and some devices also need INMETRO conformity certification. See the medical certifications page.
Should a foreign manufacturer let its Brazilian distributor hold its ANVISA registrations?
Only a Brazilian legal entity (a manufacturer or importer) can hold an ANVISA notification or registration (the "detentor"). The holder needs an ANVISA company operating authorization (AFE), files in its own name, communicates changes and keeps the technical dossier. The foreign manufacturer authorizes it through a consularized or apostilled declaration.
If your distributor is the holder, changing distributor can mean moving registrations. Many foreign manufacturers therefore use an independent holder so they can change distributors more freely. That is a commercial practice, not a legal requirement. Brazilian companies, currently more than 60, are listed on the Brazil country page.
What labeling does ANVISA require for reusable instruments?
RDC 751/2022 requires labels and instructions for use in Portuguese. They must include the Brazilian holder's name and address and, where applicable, manufacturing and expiry dates. For reusable devices, the information must cover reprocessing: cleaning, disinfection, packaging, the re-sterilization method and any limit on the number of reuses.
Label artwork and IFU are submitted with the notification or registration petition. A manufacturer exporting to Brazil therefore needs validated reprocessing instructions translated into Portuguese before filing. Some devices also need INMETRO conformity certification, so check whether that applies. See the medical certifications page.
What manufacturer documents does ANVISA ask for with imported devices?
For imported Class I and II notifications, RDC 751/2022 asks for a declaration from the legal manufacturer. It must authorize the Brazilian applicant and confirm knowledge of and compliance with B-GMP. It must be consularized or apostilled, in Portuguese, English or Spanish (or with a sworn translation), and no more than two years old if it states no validity. Class III and IV registrations also need proof of registration or free sale in the country of manufacture or sale.
Petitions missing mandatory documents can be refused without a technical query. Listed Brazilian companies are in cities such as São Paulo, Rio Claro and Ribeirão Preto; see the Brazil country page.
Which ANVISA class applies to reusable surgical instruments in Brazil?
Class I, under Rule 6 of Annex I to RDC 751/2022. Transient surgically invasive devices are Class II unless they are reusable surgical instruments (Class I) or meet higher-risk conditions, such as contact with the heart, central circulatory system or central nervous system, which can make them Class IV. Class I and II devices are notified rather than registered.
Note that RDC 751 defines reusable surgical instruments more widely than some other jurisdictions: the definition covers instruments that may or may not be connected to an active device. Where several rules apply, the strictest applies, and ANVISA may challenge the declared class. See the medical certifications page.

